+86 132 2906 5196

CU/XLPE/PVC Unarmored N2XY YJV XLPE insulated power cables

Applications

These cables are used for electricity supply in low voltage installation system, They are suitable for: 

· installation in indoors and outdoors 

· in cable ducts

· under ground

· in power and switching stations

· local energy distributions

· industrial plants

where there is no risk of mechanical damage.


 For any more information or advice please contact the office on 0086-13229065196(WhatsApp/WeChat)


Share:

Details

XLPE Insulated,PVC Sheathed Cable,0.6/1kV

The 0.6/1 KV CU/XPLE/PVC cable plays a vital role in low-voltage power transmission and distribution, widely applied in building,industrial, and infrastructure settings to ensure the reliability and safety of power systems. This Power Cable with stranded compacted copper conductor is composed of copper conductor (CU), cross-linked polyethylene insulation (XPLE), and a polyvinyl chloride sheath (PVC). For fixed installation in interiors,outdoor installation,in soil,in water and concrete,if no posterior mechanical damage is to be expected.

Construction



CU/XLPE/PVC Unarmored N2XY YJV XLPE insulated power cables

Description: N2XY, XLPE Insulated Copper Power Cable  

Conductors:Class 1 or Class 2 of plain copper,or of Class 5 of plain copper in accordance with IEC 60228.

Insulation:Cross-linked polyethylene XLPE

Insulation Colour:Natural or as required

Filler: Non-hygroscopic Material

Outer Sheath:Extruded Polyvinyl Chloride PVC&Polyethylene PE&LSZH

Colour of Sheath: Black

Voltage Rating (Uo/U):600/1000V   Test Voltage: 3.5kV for 5 minutes

Physical Properties

Maximal operating conductor Temperature: up to 70℃(PVC insulation); up to 90(XLPE insulation)

Operating Temperature Range: -5℃(PVC or LSZH sheath); -20℃(PE sheath)

Short Circuit Temperature(5 seconds maximum duration): 140-160℃(PVC insulation);250℃(XLPE insulation)

Technical Data

                                                                      0.6/1kV-2 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionShape of ConductorThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
2X1.5RE0.7 1.8 10.4 10512.12435
2X2.5RE0.7 1.8 11.2 1357.413346
2X4RE0.7 1.8 12.2 1754.614359
2X6RE0.7 1.8 13.2 2303.085575
2X10RM0.7 1.8 15.4 3401.8376100
2X16RM0.7 1.8 17.4 4801.1597130
2X25RMV0.9 1.8 20.5 7000.727130165
2X35RMV0.9 1.8 22.5 9300.524160200
2X50RMV1.0 1.8 20.3 10000.387195240
2X70RMV1.1 1.8 23.3 14000.268245290
2X95RMV1.1 1.9 26.2 19500.193305355
2X120RMV1.2 2.0 29.4 24500.153355405
2X150RMV1.4 2.2 32.6 30000.124405450
2X185RMV1.6 2.3 36.0 37000.0991465510
                                                                   0.6/1kV-3 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionShape of ConductorThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
3X1.5RE0.7 1.8 11.8 13512.12130
3X2.5RE0.7 1.8 12.7 1807.412839
3X4RE0.7 1.8 13.8 2254.613751
3X6RE0.7 1.8 14.9 3003.084764
3X10RM0.7 1.8 17.2 4301.836586
3X16RM0.7 1.8 19.4 6301.1584110
3X25RMV0.9 1.8 22.8 9400.727110140
3X35RMV0.9 1.8 25.0 12500.524135170
3X50RMV1.0 1.8 24.4 15000.387170205
3X70RMV1.1 1.9 29.4 21400.268215250
3X95RMV1.1 2.0 33.6 29600.193265300
3X120RMV1.2 2.1 35.9 37600.153310345
3X150RMV1.4 2.3 39.9 44200.124350385
3X185RMV1.6 2.4 44.1 59500.0991405435
3X240RMV1.7 2.6 51.1 71000.0754480500
3X300RMV1.8 2.7 56.1 90000.0601555565
3X400RMV2.0 3.0 62.4 100000.0470 640640
                                                                   0.6/1kV-4 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionShape of ConductorThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
4X1.5RE0.7 1.8 12.6 16012.12130
4X2.5RE0.7 1.8 13.6 2107.412839
4X4RE0.7 1.8 14.8 2804.613751
4X6RE0.7 1.8 16.0 3803.084764
4X10RM0.7 1.8 18.6 5301.836586
4X16RM0.7 1.8 21.0 8001.1584110
4X25RMV0.9 1.8 24.9 12400.727110140
4X35RMV0.9 1.8 28.3 16000.524135170
4X50RMV1.0 1.8 28.4 20000.387170205
4X70RMV1.1 2.033.1 28000.268215250
4X95RMV1.1 2.137.1 40000.193265300
4X120RMV1.2 2.240.8 50000.153310345
4X150RMV1.4 2.445.2 61000.124350385
4X185RMV1.6 2.652.1 76000.0991405435
4X240RMV1.7 2.857.8 95000.0754480500
4X300RMV1.8 3.063.5 120000.0601555565
4X400RMV2.0 3.370.9 160000.0470 640640
                                                                  0.6/1kV-5 core copper conductor XLPE insulated PVC sheathed power cable
No. of cores and nominal cross sectionShape of ConductorThickness of Insulation Thickness of SheathApprox. overall DiameterApprox. weightMax. DC resistance of conductor(20℃)Current carrying capacity
(mm2)(mm)(mm)(mm)(kg/km)(Ω/km)In Air(A)In Ground(A)
5X1.5RE0.7 1.8 11.7 17012.12130
5X2.5RE0.7 1.8 12.8 2507.412839
5X4RE0.7 1.8 14.0 3304.613751
5X6RE0.7 1.8 15.4 4603.084764
5X10RM0.7 1.8 18.8 7001.836586
5X16RM0.7 1.8 21.8 10001.1584110
5X25RMV0.9 1.8 26.2 15400.727110140
5X35RMV0.9 1.8 28.0 20800.524135170
5X50RMV1.0 1.9 32.4 27600.387170205
5X70RMV1.1 2.137.4 38900.268215250
5X95RMV1.1 2.241.7 51200.193265300
5X120RMV1.2 2.446.2 65300.153310345
5X150RMV1.4 2.653.1 80000.124350385
5X185RMV1.6 2.858.9 98000.0991405435
5X240RMV1.7 3.065.6 124000.0754480500
5X300RMV1.8 3.272.0 154500.0601555565